Multimeters
The Meter's Features
7
Table 3. Rotary Switch Positions
Switch Position
Function
Any Position When the Meter is turned on, the Meter model number briefly appears on the display.
J
AC voltage measurement
Press
A for low pass filter (K) (87 only).
L DC voltage measurement
600 mV dc voltage range
M
Press A for temperature (T) (87 only).
N Press E for continuity test.
e Resistance measurement
Press A for capacitance measurement.
O Diode test
P
AC current measurements from 0 mA to 10.00 A
Press
A for dc current measurements, from 0 mA to 10.00 A.
Q
AC current measurements from 0 μA to 6000 μA
Press
A for dc current measurements from 0 μA to 6000 μA.