Set Up the Tester
19
7
In LinkRunner Manager, select LinkRunner > Update
Software.
8
Click Select, find and select the update file (.zip
extension), then click Select.
9
Click Update.
10
When the transfer is completed, disconnect the USB
cable from the tester.
11
The screen on the tester goes blank while it installs the
update file. When the update is completed, restart the
tester.
WCaution
Do not disconnect the LinkRunner from the PC or
remove the battery during the update.
Transfer Saved Profiles to/from LinkRunner
Manager
Use LinkRunner Manager to view and configure the profiles
that are saved on the tester. To transfer profiles from the
tester to LinkRunner Manager:
1
Install the latest version of LinkRunner Manager
software on your PC. Start the software.
2
Turn on the tester.
3
Use the USB cable supplied with the tester to connect
the tester to the PC.
4
To see the profiles that are on the tester, select Tools >
Profile Manager from the LinkRunner Manager tool
bar. Profile names display under the LinkRunner Profile
Files pane.
5
Highlight a profile in this pane and select Transfer from
LinkRunner.
6
When you are done editing the profile, highlight it and
select Transfer to LinkRunner.