Fluke LinkRunner Spécifications Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 39
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
Using the PoE Feature
23
Using the PoE Feature
Power over Ethernet (PoE) is disabled by default. To enable
PoE, select Tools > PoE Configuration, and check Enable
PoE. Select the Power Sourcing Equipment (PSE) class to
verify.
If the LinkRunner is an LRAT-2000 model, you also have the
option of enabling TruePower™. TruePower applies a load
equivalent to the selected class to mimic a Powered Device
(PD). See Figures 20 and 21.
ffy47.png
Figure 20. PoE Configuration on LRAT-1000
\
ffy48.png
Figure 21. PoE Configuration on LRAT-2000
Vue de la page 29